45. BACKUP Backup parameters and save them in the EEPROM memory module.
All of the conguration setting parameters can be saved in the EEPROM memory
module for backup. The backup parameters can then be restored if they have been
inadvertently changed or corrupted. Once backup is complete the EEPROM memory
module may be removed for safe storage. All CD-3000 Series retrot control systems
are shipped with the factory default settings saved in the EEPROM memory module.
Press EXECUTE to enter the menu.
DISABLED This menu is disabled for inadvertent use. Proceed to enable.
ENABLED Press and hold MENU ( ) and MENU ( ) at the same time for 4-5 seconds.
MEMCHECK Automatically checks the EEPROM memory module for parameter type.
SURE ??? Press EXECUTE to proceed.
WAIT Automatically begins parameter backup and generates CRC value.
VERIFY Automatically veries parameter backup data and CRC value.
DONE!! Parameter backup is done and saved in the EEPROM memory module.
NO MEM! Displayed if an EEPROM memory module is not detected.
WRONG Displayed if the wrong type (parameter) of EEPROM memory module detected.
MEM TYPE Displayed if the wrong type (parameter) of EEPROM memory module detected.
WRONG Displayed if the wrong product type of EEPROM memory module detected.
PRODUCT Displayed if the wrong product type of EEPROM memory module detected.
DATA ERR Displayed when a data error occurs. Waits for key press to restart BACKUP.
NOTE: Backup all CD-3000 Series retrot control systems when conguration is
complete.
46. PRINTOUT Print various system conguration settings using a hand held infrared printer.
All CD-3000 Series retrot control systems come equipped with an infrared (I/R) LED
that provides the ability to printout all the system conguration settings, when used
in conjunction with a hand held infrared printer (Johnson System Inc., Part Number:
JS-IP). Point the hand held printer I/R LED directly at the CD-3000 Control Module
PRINTER I/R LED within 3 ft (1m).
Press EXECUTE to enter the menu.
Press MENU ( ) to scroll through and select which item(s) to printout.
SYSTEM? Prints general system information and conguration settings.
ANALOGS? Prints the channel patch for all 4 analog inputs.
Ø-PATCH? Prints the phase patch for all 96 dimmer outputs.
CURVES? Prints the dimmer curves for all 96 dimmer outputs.
F-ALARM? Prints the conguration settings for the re alarm input.
S-ALARM? Prints the conguration settings for the security alarm input.
SCENE? Prints the level settings for each of the 96 dimmers within the 20 scenes.
SCENE>01 Press EXECUTE to toggle the pointer (>) and select which scene to print.
SCENE>FL Press MENU ( ) to select the desired scene (01 to 20) or all scenes (FL).
V-LIMIT? Prints the output voltage limit settings for each of the 96 dimmer outputs.
DCPATCH? Prints the conguration settings for the dimmer to channel patch.
FD-TIME? Prints the fade time settings for each of the 20 scenes.
2 ROOM? Prints the two room assignment for each of the 96 dimmer outputs.
DMXAPAT? Prints the DMX A patch for each of the 96 dimmer outputs.
DMXBPAT? Prints the DMX B patch for each of the 96 dimmer outputs.
ALL? Printout all items at once.
PRINTING Press EXECUTE on any item to begin printing.
Press ESCAPE or RESET to exit the menu.