
www.johnsonsystems.com
10
Local Lockout Mode Activation
When the local lockout mode is activated, the control station is locked in the “OFF” state.
Any button press is ignored and the “OFF” LED ashes once to indicate local lockout mode is
activated.
Procedure:
• To activate the local lockout mode, press and hold the “OFF” button for approximately
10 seconds, until the “OFF” LED extinguishes.
• To deactivate the local lockout mode, press and hold the “OFF” button for approximately
10 seconds, until the “OFF” LED illuminates.
Remote Lockout Mode Activation
When the remote lockout mode is activated, the control station ignores all remote control station
key presses. The active LED ashes off for 0.1 seconds every 2 seconds to indicate remote
lockout mode is activated.
Procedure:
• To activate the remote lockout mode, press and hold the “DIM” button for approximately
10 seconds, until the “DIM” LED ashes off for 0.1 seconds.
• To deactivate the remote lockout mode, press and hold the “DIM” button for approximately
10 seconds, until the “DIM” LED ashes off for 0.1 seconds.
Short Circuit and Overload Protection
The control station is equipped with short circuit and overload protection. The short circuit limit is
set at 100mA with 0.6W of power dissipation. When a short circuit or overload is detected while in
the “ON” or “DIM” state, all of the button LED’s ash on and off to indicate there is a short circuit
or overload condition. The control station automatically recovers to normal operational state once
the short circuit or overload is removed.
Kommentare zu diesen Handbüchern